27

SAP Best Practices and Sizing on Nutanix

SAP-NETWEAVERAt the heart of SAP Business Suite is the SAP ERP application, which is supplemented by SAP
CRM, SAP SRM, SAP PLM, and SAP SCM. From financial accounting through manufacturing, logistics, sales, marketing, and human resources, SAP Business Suite manages all the key mission-critical business processes that occur each day in companies around the world. SAP NetWeaver is the technical foundation for many SAP applications; it is a solution stack of SAP’s technology products.

Deploying and operating SAP Business Suite applications in your environment is not a trivial task. Nutanix enterprise cloud platforms provide the reliability, predictability, and performance that the SAP Business Suite demands, all with an efficient and elegant management interface.

The Nutanix platform offers SAP customers a range of benefits, including:

• Lower risk and cost on the first hyperconverged platform SAP-certified for NetWeaver applications.
• A turnkey validated framework that dramatically reduces the time to deploy your SAP
applications.
• Mission-critical availability with a self-healing foundation and VM-centric data protection, including support for the top enterprise backup solutions.
• Flexibility to choose among industry-leading SAP-supported hypervisors.
• Simplified operations, including application- and VM-level metrics alongside single-click
provisioning and upgrades.
• Reduced TCO from infrastructure right-sized for your SAP workload.
• A best-in-class worldwide support system whose knowledge and commitment to customer service has earned the Omega NorthFace Scoreboard Award for three consecutive years.

Read the Solution Note for best practices with both Hyper-V and VMware and sizing guidelines => SAP Solution Note

Apr
24

Save Your Time With Nutanix Automatic Support

Best Industry Support

The feature known as Pulse is enabled by default and sends cluster status information automatically to Nutanix customer support. After you have completed initial setup, created a cluster, and opened ports 80 or 8443 in your firewall, AOS sends a Pulse message from each cluster once every 24 hours. Each message includes cluster configuration and health status that can be used by Nutanix Support to address any cluster operation issues.

AOS can also send automatic alert email notifications to Nutanix Support by default through ports 80 or 8443. Like Pulse, any configured firewall must have these ports open. Some examples of conditions that will automatically generate a proactive case with Nutanix support with a Priority Level P4.

The Stargate process is down for more than 3 hours
Curator scan fails
Hardware Clock Failure
Faulty RAM module
Power Supply failure
Unable to fetch IPMI SDR repository (IPMI Error)
HyperV networking
System operations
Disk Capacity > 90%
Bad Drive

You can optionally use your own SMTP server to send Pulse and alert notifications. If you do not or cannot configure an SMTP server, another option is to implement an HTTP proxy as part of your overall support scheme.

While the best thing is never to a get a call, 2nd best is not waiting in line to open a ticket. Have a great week!

Apr
23

3rd Generation Erasure Coding (EC-X) – What’s Next?

Take time for all things: great haste makes great waste. Benjamin Franklin

I don’t profess to be an erasure coding genius but I know enough that it would be very poor choice for workloads that has lots of overwrites, cycling thru lots of snapshots and running erasure coding inline would really only be suited for a WORM application which is not typical for a lot of virtual environments. Nutanix first released erasure coding as EC-X in AOS 4.1.3 as a tech preview and has learned lots along the way with it’s agile software development method.

With AOS 4.6.1 being released on April 18th more improvements were added for EC-X.

    Faster reclamation – simply put if your EC strip is changed holes start appearing in your strip. You need an efficient of plugging the holes and allow them to be encoded again. /ol>

      Advanced EC-X selection heuristics – Nutanix engineering has come up with an algorithm to determine to use blocks form the same virtual hard drive or blocks from through out the container. Better selection reduces the need to fix strips and reduce CPU load on the cluster. This also helps to fix the problem of cycling through lots of snapshots.
      Strip compaction – If a EC-X strip has too many holes it won’t even try to fill the gaps. It will determine to move the data out of the strip

    With the mission to enable enterprise cloud more and more of the features are becoming self adjusting to truly allow for set and forget. The end goal is to have all the features turned on and let the system side. I am looking forward to watching the announcements at .Next in June.

    come to  .Next

Apr
23

Operations Getting Down With DJ RunC & ContainerD

Rundmc_2

runC and containerd does sound like some rappers from the 80’s. While in the land of hip hop Run–D.M.C. was legendary in creating new school rap, Docker has thrown it’s interia behind runC and containerD to pave the way for future success. runC is an implementation of the Open Container Initiative (OCI) spec which Docker has donated a huge chunk of their own work to the project. runC is a standalone binary that allows you run a single OCI container. This is big because now everyone has a standard way to run a container which creates better portability and creates good code hygiene.

containerD is a new piece of infrastructure plumbing that allows you to run multiple containers using runC. It’s kinda like a simple init system. containterD takes care of the simple CRUD operations against containers but image management still lives with the Docker Engine. containerD is also event driven so you can build untop of it.

2016-04-22_23-31-30

With the release of Docker 1.11 runC and contianerD is fully integrated. I think this important because if your going to pick a horse in the container race you have a company in Docker that is leading with committers for OCI which is essentially helping to set direction for containers. On the operations side of the house if I have to upgrade the Docker Engine, there is now a road map to have an upgrade without affecting your running containers. It’s great containers can run and die but it’s even better if they never fail 🙂

Docker 1.11 also added DNS round robin load balancing. While may it seems crude to the likes of a F5 or Netscaler engineer I always find simple wins and see it used in lots of places. If you give multiple containers the same alias, Docker’s service discovery will return the addresses of all of the containers for round-robin DNS.

I think the the 1.11 release of Docker will continue to build great things. Let’s just hope it doesn’t lead to over played Run–D.M.C spoof shirts.

Apr
17

Quickly Pin Your Virtual Hard Drive To Flash #vExpert #NTC

If you need to ensure performance with Flash Mode here is a quick way to get your job done.

Find the disk UUID
ncli virtual-disk ls | grep -B 3 -A 6

pin-flash1

Example
ncli virtual-disk ls | grep m1_8 -B 3 -A 6

Virtual Disk Id : 00052faf-34c2-58fc-64dd-0cc47a673b8c::313a49:6000C29b-93c9-bfe1-58d9-e718993e5a06
Virtual Disk Uuid : 1dc11a7f-63ac-422a-ac27-442d5fcfc91a
Virtual Disk Path : /hdfs/cdh-m1/cdh-m1_8.vmdk
Attached VM Name : cdh-m1
Cluster Uuid : 00052faf-34c2-58fc-64dd-0cc47a673b8c
Virtual Disk Capacity : 268435456000
Pinning Enabled : Flase

Set 25 GB to pin to flash of the vdisk
ncli virtual-disk update-pinning id=00052faf-34c2-58fc-64dd-0cc47a673b8c::313a49:6000C29b-93c9-bfe1-58d9-e718993e5a06 pinned-space=25 tier-name=SSD-SATA

Pinned Space is in GB.

In this case I was pinning a Hadoop NameNode directories to flash because I wanted to include their physical node in the cluster to help with replication traffic.

Apr
08

Horizon 7: Notes & important cliff notes from the docs

I was travelling last week and when I was sitting on the plane reviewing some Horzion 7 docs. I thought I would capture the bits that tend to make or break your installation. The below bits are good reminders on what to do and what not to do.

NOTE When installing replicated View Connection Server instances, you must usually configure the instances in the same physical location and connect them over a high-performance LAN. Otherwise, latency issues could cause the View LDAP configurations on View Connection Server instances to become inconsistent. A user could be denied access when connecting to a View Connection Server instance with an out-of-date configuration

IMPORTANT The physical or virtual machine that hosts View Connection Server must have an IP address
that does not change. In an IPv4 environment, configure a static IP address. In an IPv6 environment, machines automatically get IP addresses that do not change.

IMPORTANT To use a group of replicated View Connection Server instances across a WAN, MAN (metropolitan area network), or other non-LAN, in scenarios where a View deployment needs to span datacenters, you must use the Cloud Pod Architecture feature. You can link together 25 View pods to provide a single large desktop brokering and management environment for five geographically distant sites and provide desktops and applications for up to 50,000 users.

Cloud Pod Architecture

NOTE Windows Server 2008 R2 with no service pack is no longer supported.

To use View Administrator with your Web browser, you must install Adobe Flash Player 10.1 or later

IMPORTANT If you create the View Composer database on the same SQL Server instance as vCenter Server,
do not overwrite the vCenter Server database.

IMPORTANT To run View in an IPv6 environment, you must specify IPv6 when you install all View
components. – you can’t change it after the fact.

NOTE View does not require you to enter an IPv6 address in any administrative tasks. In cases where you can specify either a fully qualified domain name (FQDN) or an IPv6 address, it is highly recommended that you specify an FQDN to avoid potential errors.

NOTE To ensure that View runs in FIPS (Federal Information Processing Standard) mode, you must enable FIPS when you install all View components.

NOTE You might need to set the UPN for built-in Active Directory accounts, even if the certificate is issued
from the same domain. Built-in accounts, including Administrator, do not have a UPN set by default.

Enrollment Server Installation

NOTE Because this feature requires that a certificate authority also be set up,and specific configuration performed, the installation procedure for the enrollment server is provided in the View Administration document,

NOTE View Connection Server does not make, nor does it require, any schema or configuration updates to Active Directory.

IMPORTANT You will need the data recovery password to keep View operating and avoid downtime in
a Business Continuity and Disaster Recovery (BCDR) scenario. You can provide a password reminder
with the password when you install View Connection Server.

IMPORTANT When you perform a silent installation, the full command line, including the data recovery
password, is logged in the installer’s vminst.log file. After the installation is complete, either delete this
log file or change the data recovery password by using View Administrator.

NOTE Replication functionality is provided by View LDAP, which uses the same replication technology as
Active Directory.

NOTE You cannot pair an older version of security server with the current version of View Connection
Server. If you configure a pairing password on the current version of View Connecton Server and try to install an older version of security server, the pairing password will be invalid.

IMPORTANT If you do not provide the security server pairing password to the View Connection Server installation program within the password timeout period, the password becomes invalid and you must configure a new password.

IMPORTANT If you use a load balancer, it must have an IP address that does not change. In an IPv4 environment, configure a static IP address. In an IPv6 environment, machines automatically get IP addresses that do not change.

NOTE If the installation is cancelled or aborted, you might have to remove IPsec rules for the security server
before you can begin the installation again. Take this step even if you already removed IPsec rules prior to
reinstalling or upgrading security server.

CAUTION If you remove the IPsec rules for an active security server, all communication with the security
server is lost until you upgrade or reinstall the security server. Therefore, if you use a load balancer to manage a group of security servers, perform this procedure on one server and then upgrade that server before removing IPsec rules for the next server. You can remove servers from production and add them back one-by-one in this manner to avoid requiring any downtime for your end users.

IMPORTANT Replace the default certificate as soon as possible. The default certificate is not signed by a
Certificate Authority (CA). Use of certificates that are not signed by a CA can allow untrusted parties to intercept traffic by masquerading as your server.

IMPORTANT To configure View Connection Server or security server to use a certificate, you must change the
certificate Friendly name to vdm. Also, the certificate must have an accompanying private key.

IMPORTANT If you plan to use this feature and you are using multiple View pods that share some ESXi hosts,
you must enable the View Storage Accelerator feature for all pools that are on the shared ESXi hosts. Having
inconsistent settings in multiple pods can cause instability of the virtual machines on the shared ESXi hosts.

View Storage Accelerator is now qualified to work in configurations that use View replica tiering, in which
replicas are stored on a separate datastore than linked clones. Although the performance benefits of using
View Storage Accelerator with View replica tiering are not materially significant, certain capacity-related
benefits might be realized by storing the replicas on a separate datastore. Hence, this combination is tested
and supported.

NOTE You can also use Access Point appliances, rather than security servers, for secure external access to Horizon 7 servers and desktops. If you use Access Point appliances, you must disable the secure gateways on View Connection Server instances and enable these gateways on the Access Point appliances.

IMPORTANT Do not change the JVM heap size on 64-bit Windows Server computers. Changing this value
might make View Connection Server behavior unstable. On 64-bit computers, the View Connection Server
service sets the JVM heap size to accord with the physical memory.

IMPORTANT Syslog data is sent across the network without software-based encryption, and might contain
sensitive data, such as user names. VMware recommends using link-layer security, such as IPSEC, to avoid
the possibility of this data being monitored on the network.

IMPORTANT View Composer is an optional component. If you plan to provision instant clones, you do not need to install View Composer.

NOTE Virtual Volumes is compatible with the View storage accelerator feature but not with the space efficient
disk format feature, which reclaims disk space by wiping and shrinking disks.

NOTE Instant clones do not support Virtual Volumes.